- 2100 TP The importance of matching battery and charger cannot be underestimated – so when the world’s leading manufacturer of motive power batteries dedicates years of research to this cause, designing and manufacturing compatible chargers itself in house, you can be assured of the optimum battery performance and life.
. 15935 Answers Resource: 'Y05' will be an indication of a water heat sensor (NTC) error, or Heating system Circuit failing. Examine the Water Heat Sensor and verify cable connections to the Drinking water Heat range Sensor. To gain access to, you will have to UNPLUG your washer and eliminate the lower gain access to board under the door. The -panel comes off by removing the screws under the bottom level edge.
Tip: If you spot a engine block of timber under each top foot of the washer, it will create gain access to to the screws much easier. If the cell stays, a touch on the sides will knock it free of charge.
The section will fall down after that come away from. The sensor (NTC) will be situated at the base of the clean bathtub in the front side on the heating component. This will be a little square formed plug between the heating element terminals. Unplug the wire funnel and take a opposition check.
Blood pressure measurements will become as follows: Temperatures Meter Reading through 32°F (0°M) 35.9 E ohms 86°Y (30°D) 9.7 T ohms 104°N (40°C) 6.6 K ohms 122°F (50°G) 4.6 E ohms 140°N (60°M) 3.2 K ohms 158°Y (70°Chemical) 2.3 E ohms 203°F (95°M) 1 E ohms Roughly.aróund 9K ohms at area heat if I'm reading the chart correctly. Get readings as outlined and furthermore double check the connector to make certain it will be not really oxidized. Try out cleaning the put and reconnecting to notice if the error code will go away. If not, you will probably have got to change the sensor. lf the sensor bank checks good, take a reading through across the heating element terminals. It should suggest about 15 ohms.
Lastly, get rid of the washing machine top cell by getting rid of the three anchoring screws holding the screen in place in the rear. Once the screws are eliminated, slip the cell back then away from. Locate the Main Control Device (CCU) straight behind the clean tub. Take a resistance check out at the Heating system Element Solenoid by getting rid of connector 9 from the CCU (this is usually the 2nd connector from the Best as dealing with from the front). A reading across check points 1 2 should furthermore study 15 ohms Thanks a lot for making use of FixYa - a 4 THUMBS ranking is appreciated for answering your FREE question.!!!! Posted on Sep 29, 2010. 3053 Answers Resource: Hello, Mike I are attempting to help you out here.
Probably this will help some? I have always been know on Fixya as the cleaning expert pro. Which means I spend my personal personal time to look for out customers that maybe have not had there problem yet solved by the some other fantastic great professionals. I do this on my own for free of charge.
Think that of me ás a Specialized Trouble Present shooter. I possess found out that it shows up that a lot of clients value my initiatives and assist. So, I thought I would consider some of my very own personal time to observe if I can assist you.
Even though this Educational site may not really possess your exact model or brand, But this site will help you a lot. Here is certainly the web site link about everything you want to understand about cleaning machines and perhaps yours, from to problems capturing it. Make sure you if this helped you at aIl, if you cán discover the period and in your heart to price my assist and some kind words created would end up being valued for my free assist, I would enjoy it.
Like I stated I simply try to assist, If anything this is good information for potential future difficulties. Vue xstream 2016. If you felt that my free help has been a waistline of time for you, l'm sorry. l do not really to assist people on the site, I do it result in I like to help and probably make a smile on someones face. Here will be also my direct link to my personal webpages of various other places of my expertise for other complications you might have in Automotive, Appliance, and Electronics. Drop In anytime for my help.
Thanks Mike Published on Nov 09, 2011. Y05 - NTC failure (SC/OC) All home appliances managed by the electronics measure the temperature using a thermistors. These thermistors modifications resistance based on the temp.
There are usually two kinds of thérmistors, NTC ánd PTC. NTC offers a harmful temp coefficient which means that with escalating heat the opposition reducing (used in cleaning machine, dishwasher, drier, refrigerator.etc). PTC offers a beneficial heat coefficient which indicates that with improving temperatures the resistance growing (used in oven, fridge for beginning compressor.etc). If you look in the table below, it is definitely very clear that the level of resistance value of 100 ohm indicates that is definitely NTC faulty. So, I really do not really realize how it is usually achievable that the level of resistance raises with heat range?
Resistance of NTC depending on heat range 0 °G 35.9 kohm 30 °Chemical 9.8 kohm 40 °M 6.6 kohm 50 °D 4.6 kohm 60 °C 3.2 kohm 70 °Chemical 2.3 kohm 95 °G 1.1 kohm Dado Jul 16, 2015. Problem Codes Significance of Fault Code N01 Internal Shorted Cell Battery power - Cannot be charged.
Have got battery checked by licensed auto services center. Excessive Weight on Battery power While Getting - Check load. N02 Poor Battery Connection - Examine battery connection. Battery pack Voltage Device Lower to Take Cost - Possess battery examined by certified auto assistance repair. F03 Internal Open Cell - Possess battery checked by qualified auto support center.
Sulfated Condition - Battery requires to end up being reconditioned. F04 Overtime Condition - Electric battery will not really acknowledge a charge after 18 hours of continous charging. Battery power may possess internal harm. Have got battery checked by certified auto center. Battery Cost Rate is definitely Set Too Lower - Fixed charger to increased charge rate.
F05 Overheated Condition - Disconnect charger and permit to interesting for 30 minutes. Examine for ample ventilation.
F06 Reverse Polarity N07 Alternator Output is Out of Standard Operation Range Operation Requirements I=I=I=I Battery power Reconditioning - (The characters DES will screen for the very first three mere seconds) I-I-l-I Alternator VoItage Check out OOO Charger Standby Total Battery Completely Charged Sep 21, 2008.